Section 5.0 Troubleshooting


Symptom

Possible Cause

Corrective Action


I

Smoke in room


1.

Down draft


1.

Upgrade chimney

2.

Chimney blocked

2.

Clean chimney

3.

Chimney damper shut

3.

Open or remove damper

4.

Baffle out of position

4.

Correctly position baffle

5.

New paint is curing

5.

Refer to instructions

II

Wood burns
poorly or is slow
to start or no
heat

1.

Low draw

2.

Wet or decayed wood

3.

Blocked intake air

1.

Upgrade chimney

2.

Use proper fuel

3.

Check intake air supply
by removing fan from
insert and opening a
window

III

Dirty glass

1.

Insert is being under fired

1.

Refer to instructions

IV

Wood burns too
fast

1.

Too much draft in
chimney

1.

Consult a qualified
technician.