INSTALLING THE APPLIANCE (Clearance to sides and shelves) Super Hot Toaster Mk4


The minimum clearance to any combustible material to the side of the appliance must be 150mm (Fig. 12).

The minimum clearance to any non-combustible material around the perimeter of the appliance must be 75mm.

The minimal clearance to the underside of a 150mm depth combustible shelf from the hearth must be 790mm. Add 12.5mm to this
clearance for every 25mm increased depth of shelf (Fig 12). A `SHELF CHART’ (Fig 13) is provided to aid in calculating shelf clearances.
















2.4.3

INSTALLING THE APPLIANCE (Hearth clearances)

A non-combustible hearth with a minimum thickness of 12.5mm and having a perimeter of 50mm above floor level is required to discourage
placing carpets or combustible materials close to the hearth. The width must be a minimum of 150mm either side of the fireplace opening
and a depth of 300mm from the front face of the fire opening (Fig 14).



















FIRE

OPENING

HEARTH AREA

150mm

300mm

Fig. 14

Minimum hearth height - 50mm

Minimum hearth width - 805mm

Minimum hearth thickness - 12.5mm

790mm

150mm

Add 12.5mm to clearance for every
25mm increased depth of shelf

Fig. 12

802.5

815

827.5

840

852.5

175 200 225

250

275

SHELF CHART

Shelf Depth 150

All dimensions are in MM

Shelf Height 790

Fig. 13