What to do before calling for service

Low capacity

Check for restricted drain or standing water
in the bin

Clean the air cooled condenser fins

Clean the ice making system

No ice

Check on-off switch

Check electrical breaker

If the Check Water light is flashing Red,
check water supply. The control system
checks for water every 20 minutes. When the
water supply is restored, the machine will
automatically restart ice making.

If the all the lights are flashing, the auger
motor has overloaded or is not operating.
Call for service.*

Time to Clean light is on

Clean the ice making system.

* Technical note: One blink and repeat indicates an
overload, two blinks and repeat indicates an open
motor. Reset by pressing the on/off button.