page 25

Technical Specifications

Environmental requirement:

Operating temperature: 10 degrees Celsius to 35 degrees Celsius

Replacing a power supply module

To replace the power supply module (PSM), do the following:

1. If you have two power supply modules, verify which one has failed. The LED next to the green handle is lit

red if the PSM failed.

2. Disconnect the power cord.

Note: You only need to disconnect the power cord of the PSM that failed. The power cord of the functioning
PSM can remain plugged.

3. Slide the green safety lock to the left.

4. Grasp the green handle and pull the PSM out.

5. Take the new PSM and insert it into the box. Make sure to keep the green safety lock pressed to the left

while inserting the PSM.

Dialogic

®

3000 Media Gateways

Dialogic

®

4000 Media Gateways

CPU

Intel Pentium IV processor; 2.8 GHz

Intel Xeon 5160 Dual Core processor; 3.0GHz

Memory

1 GB DDR SDRAM (400MHz)

2 GB DDR2 ECC SDRAM (667MHz)

Dimensions in mm

Height:

44

44

Width:

430

430

Length:

390

508

External interface

2 USB (2.0) ports
VGA port

RS232 Serial port

2 x Gigabit-Ethernet ports

3 USB (2.0) ports
VGA port

RS232 Serial port

4 x Gigabit-Ethernet ports

Internal interface

32 bit; PCI (5 V)

64 bit; PCI (3.3 V)

Power supply

100-240 Vac

50/60 Hz

4 A

2 power supplies; each with:

100-240 Vac

50/60 Hz

4/2 A