Issue 2, January 2015

Model 45DR User Guide

Page 10

Studio Technologies, Inc.

Protecting the Enclosure

The Model 45DR is shipped as a self-

contained unit suitable for portable use

or placement in a semi-permanent loca-

tion. Installed on the bottom of the chassis

are screw-on “bump on” protectors (also

known as “rubber feet”). These are useful

if the unit is going to be placed on surfaces

where scratching of either the Model 45DR

or the surface material could take place.

The “feet” can be removed, without the use

of a tool, when rack- or custom-mounting

the unit.

Rack Mounting the

Model 45DR

For permanent or mobile applications it

might be desirable to mount one or two

Model 45DR units into one space (1U) of

a 19-inch rack enclosure. Two rack-mount

front panels, purchased separately, are

available from Studio Technologies. The

following provides details on how to install

and use the panels.
To attach a Model 45DR unit to the single-

unit rack-mount panel, begin the process

by using a 5/64-inch hex wrench to remove

the four 4-40 thread hex-head machine

screws that hold the standard front panel

to the chassis. Note that the screws might

be quite tightly affixed. Ensure that a good-

quality hex wrench is used and press and

hold it firmly while turning counterclock-

wise. Unless this recommendation is fol-

lowed the wrench can “cam out” and the

head could be “stripped.”
Using the screws that were just removed,

attach the rack-adapter front panel to the

Model 45DR’s chassis. To prevent damage

care is required when aligning the front

panel with the LEDs and auto null push-

button switch that protrude through both

the Model 45DR’s chassis and front panel.

Tighten the four screws only after a careful

inspection ensures that the switch and all 26

of the LEDs protrude through the front panel

without interference. To allow vertical clear-

ance in the associated rack, remove the four

“bump on” protectors from the bottom of

the chassis. They are removed by using the

fingers to rotate them counter-clockwise; no

tool is required. Carefully protect and store

the standard front panel, along with the

“bump on” protectors, for possible later use.
Mounting a Model 45DR to a dual-unit rack-

mount panel follows the same procedure

but will apply to two units. Store both of the

removed standard front panels and the eight

“bump on” protectors for possible later use.

Note that on the rack-panels graphics the

unit on the left is designated as A while the

unit on the right is designated as B. This is

provided so that each can be easily identi-

fied during installation, troubleshooting, and

operation.
Once the desired one or two Model 45DR

units have been installed in a rack-mount

front panel, the assembly can be mounted

into the designated equipment rack. One

space (“1U” or 1.75 vertical inches) in

a standard 19-inch equipment rack is

required. Secure the front panel into the

equipment rack using two mounting screws

per side.

Ethernet Connection

An Ethernet connection that supports

100BASE-TX (100 Mb/s over twisted-pair)

is required for the Model 45DR’s Dante

Audio-over-Ethernet connectivity. A

10BASE-T connection is not sufficient for

Model 45DR operation. A 1000BASE-T

(“GigE”) connection is not supported