Remote switch – Sun Pumps SCP 48-18-48Y BC User Manual
Page 17
Remote Switch
(This circuit is not typically used with pool pumps)
The Remote Switch interface can serve as an automatic system shutdown when used with a water storage tank
mounted float switch, a pressure switch or it can also serve as a manual system shutdown with a remote system
ON/OFF toggle switch. The remote logic circuit allows the use of standard “Pump-Up or Pump Down” float
switches. Please refer to the following operation scenarios for configuration options.
With switch number 1 in the OFF position, the controller is configured to accommodate a Normally Open (N.O.)
float switch or remote toggle switch. In this configuration the controller will operate as follows:
PUMP ON
float switch open = water tank low = pump ON
PUMP OFF
float switch closed = water tank high = pump OFF
With switch number 1 in the ON position, the controller is configured to accommodate a Normally Closed (N.C.)
float switch, pressure switch or remote toggle switch. In this configuration the controller will operate as follows:
PUMP ON
switch closed = water tank low = pump ON
PUMP OFF
switch open = water tank high = pump OFF
A one minute minimum timeout is default for this feature but is modifiable by switches 3 and 4 to 10 or 30
minutes respectively. At certain times the controller may be off for up to 14 minutes depending on various factors
in the controller program. This timeout applies to remote switch and low water cutoff.
Low-Power Shut-Down/Sensorless Low Water Cut-Off Circuit (LPLW)
The Low-Power Shut-Down/ Low Water Cut-Off Circuit (LPLW) turns the pump off any time the controller
output power drops below a functional level. This may be caused by lack of power from the solar panels or from
running out of water. This protects the pump in stall conditions and saves wear on the system when no or very
little water is being pumped. This feature must be adjusted for your specific application.
This feature is always monitoring the output of the motor. If you are not interested in using this feature turn the
“LP Adj” trim pot fully counter-clockwise. This will give the pump the minimum low power set point possible.
SCP Pool Pumps do not normally use this feature.
LPLW Adjustment
The Low Water Cut-Off Circuit and the Low Power Shut-Down circuit are adjusted using the same trim pot
labeled “LP Adj.” on the controller. The default is the arrow pointing straight up. This is sufficient for most
systems but adjustment will maximize the life and output of your system. Follow the steps below to adjust this
feature.
1. Turn the “LP Adj.” trim pot fully counter clockwise.
2. Turn the “Speed Control” trim pot counter clockwise until the pump is pumping the desired minimum
flow. This may be down to 0 gal/min but is not recommended for proper pump cooling.
3. Turn the “LP Adj.” trim pot clockwise until the pump shuts off.
4. Reset the “Speed Control” trim pot back to the desired position.
- SCP 100-60-180 BV SCP 115-60-240 BV SCP 50-50-120 BC SCP 58-51-48 BC SCP 62-42-105 BC SCP 67-50-120 BC SCP 75-40-105 BC SCP 80-55-180 BC SCP 86-55-180 BV SCP 86-65-180 BC SCP 94-37-120 BV MTR BLM-SB-103S-120Y MTR BLM-SB-203S-180 MTR BLM-SB-303S-240 PCC-120BLS-M2 PCC-180BLS-M2 PCC-240BLS-M2 MTR-BLM-SF-153C-120 MTR-BLM-SF-153C-90Y MTR-BLM-SF-303C-180 MTR-BLM-SF-353C-240 MTR-BLM-SF-153J-120 MTR-BLM-SF-153J-90Y MTR-BLM-SF-303J-180 MTR-BLM-SF-353J-240 PCA-120-BLS-M2 PCA-60-BLS-M2 MTR BLM-SB-073S-60 MTR BLM-SB-153S-120 SCS 10-165-60 BL SCS 10-600-240 BL SCS 14-95-60 BL SCS 18-90-60 BL SCS 7-210-60 BL