Installation, Continued – Desa EFS26NRA User Manual

Page 15

Advertising
background image

www.desatech.com

113110-01A

15

INSTALLATION

Continued

Figure 17 - Installing Switch Plate to

Valve Cover Shield

Valve Cover
Shield

Switch
Plate

Screw

For Built-In Installation

WARNING: A licensed elec-

trician must connect the wiring
harness to electrical supply fol-
lowing all local codes. Electri-
cian must provide a clamp on
the box cover to secure the wir-
ing. Wiring should be routed
through the bushing in the hole
on the outer casing of fireplace.

1.

Install a snap bushing found in hardware kit
into one of the holes on rear of valve cover
shield. The other hole is for a strain relief
clamp (not supplied) to secure incoming elec-
trical supply.

2.

Follow steps 2 through 6 in Installing Blower
Accessory
, page 14.

3.

A licensed electrician must follow the wiring
diagram to connect incoming electrical sup-
ply to fan kit wiring harness (see Figure 18).

4.

Plug power cord to the outlet receptacle (not
provided) as shown in Figure 19. Wind the
extra power cord and tie with plastic wire strap
(see Figure 19). Set the power cord bundle
between the burner bracket and outer casing,
away from the burner.

5.

Test to make sure the blower is working
properly.

6.

Reinstall upper louver assembly (see Figure 14,
page 13) and close lower louver.

Red

Red

Fan Switch

(Auto/Off/On)

Blue

Blue

Thermostat

Switch

(N.O.)

Green

White

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

3

Auto

Figure 19 - Installing Blower Bracket

Assembly

Figure 18 - Wiring Diagram For Blower

Accessory Built-In Installation

Plastic Wire Strap

Wire Harness

Lower
Louver Door

Blower
Bracket
Assembly

Screw

Wire
Harness

Switch
Plate

Switch

Blue

Red

Outlet
Receptacle
(not included)

Power Cord

Black

Clamp
Connector
(not
included)

8.

Reconnect red wire to switch position 3. Re-
connect blue wire to switch position 1. Re-
connect green and white wires.

9.

Install the switch plate on the valve cover shield
with 2 #10 screws provided (see Figure 17).
Route power cord out of the cabinet by insert-
ing it through the bushing on the outer casing
(see Figure 15, page 14). Plug fan kit into 120-
Volt grounded power supply and test operation.

Note:

When switch is in the AUTO position,

the fan will start after the fireplace has run for
a few moments. The fan will continue to run
for several moments after the fireplace has been
turned off. When switch is in the ON position,
the fan will run until turned to OFF. Reinstall
upper louver assembly (see Figure 14, page 13)
and branch support. Close lower louver door.

Extension Cord

Use extension cord if needed. The cord must have a
three-prong, grounding plug and a three-hole recep-
tacle. Make sure cord is in good shape. It must be
heavy enough to carry the current needed. An under-
sized cord will cause a drop in line voltage. This
will result in loss of power and overheating. Use a
No. 16 AWG cord for lengths less than 50 feet.