Dpa 4000 series, Technical specifications – Dynacord Professional Power Amplifiers User Manual

Page 68

Advertising
background image

dPa 4000 s

eries

68

DPA 4000 Series

technical specifications

General

DPA 4410

DPA 4411

DPA 4120

DPA 4140

Load Impedance

100 Ω / 100 V, 50 Ω / 70 V

25 Ω / 50 V, 4 Ω / 20 V

50 Ω / 100 V, 25 Ω / 70 V

12.5 Ω / 50 V, 4 Ω / 28 V

25 Ω / 100 V, 12.5 Ω / 70 V

6.25 Ω / 50 V, 4 Ω / 40 V

Rated Output Power (Mains)

4 x 100 W

(acc. to IEC 268-3 / 19.4)

2 x 200 W configurable

1 x 200 W + 2 x 100 W configurable

200 W

(acc. to IEC 268-3 / 19.4)

400 W

(acc. to IEC 268-3 / 19.4)

Power Output Characteristics

balanced, floating

Input Characteristics

balanced

Input Sensitivity

775 mV / 0 dBu

Input Impedance

≥ 10 kΩ

Distortion @ 1 kHz and Nom. Outp. Power

≤ 1 %

Interference Voltage (A)

≤ 1.2 mV / -56 dBu

Frequency Response

60 Hz .. 20 kHz

Load Impedance (monitor)

600 Ω

Nominal Output Voltage (monitor)

2 V / + 8.2 dBu

Output Characteristics (monitor)

unbalanced

electronically balanced

Output Stage Topology

Class-AB, Transformer, Floating

Power Requirements

115 V / 230 V AC, ±10 % / 50 - 60 Hz or 24 V DC, -10 / +30 %

Mains Power Consumption

1010 VA at nominal output

520 VA at nominal output

1020 VA at nominal output

377 VA driven at -10 dB

200 VA driven at -10 dB

380 VA driven at -10 dB

62 VA no signal

67 VA no signal

30 VA no signal

44 VA no signal

24 V DC Power Consumption

18 A at nominal output

9.1 A at nominal output

17.3 A at nominal output

7.5 A driven at -10 dB

3.7 A driven at -10 dB

7.1 A driven at -10 dB

1.0 A no signal / 2.5 mA in

stand-by

1.1 A no signal / 2.5 mA in

stand-by

0.4 A no signal / 2.5 mA in

stand-by

0.6 A no signal / 2.5 mA in

stand-by

Protection

High Temperature, Inrush Current Limiters, Short Circuit

Cooling

Front-to-Rear, temperature controlled

Ambient Temperature Limits

+5° C ... +40° C (40° F... 105° F)

Safety Class

I

Dimensions (WxHxD), mm

483 x 132 x 345 mm, 19” / 3 HU

Installation Depth without Connectors

340 mm

Installation Depth including Connectors

max. 410 mm

Weight

22.3 kg

22.5 kg

13.2 kg

16.7 kg

Color

anthracite

Optional

Extension-kits for the DPA 4410 / DPA 4411:
NRS 90206 Pilot Tone Monitoring (for four amplifiers)
NRS 90207 Ground-Fault Monitoring (for four amplifiers)
NRS 90227 Output Transformer (floating, balanced monitor
outputs) for DPA 4411

Additional Version DPA 4411:
DPA 4411N: DPA 4411 + NRS 90206 + NRS 90207

Extension-kits for the DPA 4120 / DPA 4140:
NRS 90222 Remote module (note: not supplied with the DPA
4120/DPA 4140)
NRS 90224 Pilot tone & ground-fault monitoring (note: not
supplied with the DPA 4120/DPA 4140)
NRS 90225 Standard input module (note: not supplied with the
DPA 4120/DPA 4140)
NRS 90227 Output transformer (floating, balanced monitor
output)

Additional Version DPA 4140:
DPA 4140N: DPA 4140 + NRS 90222 + NRS 90224

Advertising