5.4

Lifting and moving the pump

For lifting and moving the pump, it has been fitted with a
lifting point. This lifting point (A) is fitted on the upper
side of the cover. The maximum rating of the lifting point
depends on the pump model. Make sure that the total of
weight to be moved will not exceed this maximum
rating.

For the weights, refer to §

10.1.5

.

The complete hose pump, i.e. pump head, gearbox and
electric motor, must be lifted using the lifting point of the
pump head plus additional support using suitably rated
straps or slings (A). Never exceed the maximum rating
of the lifting point of the pump head.

Maximum permissible loads [N] on the pump

flange

Force

Bredel

40

Bredel

50

Bredel

65

Bredel

80

Bredel

100

F1

1000

1400

1400

2000

2000

F2

200

300

300

400

400

F3

500

700

700

1000

1000

Maximum rating of the lifting point of the pump

head

Bredel

40

Bredel

50

Bredel

65

Bredel

80

Bredel

100

200 kg

390 kg

670 kg

1020 kg

1580 kg