Troubleshooting

16

3A1186F

Troubleshooting

General

Problem

Cause

Solution

Unit doesn’t prime

Airleak due to loose suction nut

Tighten suction nut.

Airleak due to worn o-rings

Replace o-ring (108526) on suction seat and
suction hose (331290), if so equipped.

Hole in suction hose

Service outlet valve suction assembly.

Stuck or fouled balls

Unit primes but has poor or no
pressure

Pressure set too low

Turn up pressure.

Filter(s) are clogged

Clean or replace gun filter, inlet filter, and/or
manifold filter.

Outlet valve fouled/worn.

Service outlet valve.

Prime/pressure relief valve
bypassing

Clean or replace prime valve.

Packings and/or piston worn

Tighten packing nut, repack unit.

Unit does not maintain good
spraying pressure

Blown spray tip

Replace spray tip.

Packings and/or pistons worn

Repack unit.

Upper seat worn

Replace upper seat.