Comdump – Elo TouchSystems MonitorMouse FOR WINDOWS NT Version 2.0 User Manual
Page 29
24
Appendix A - Troubleshooting
It is possible that non-linearity or other problems may exist even if data is being
reported to the computer. From the coordinate display, you can determine which
corner is the origin and watch both X and Y increase steadily as you slide your
finger to the diagonally opposite corner. Check the other two corners to make sure
their coordinates look correct and the touchscreen appears linear in each axis. If
the coordinates appear to be meaningless, try changing the Base I/O Port address
of the controller. Another device may be contending for the same I/O address.
See the IntelliTouch Product Manual or the AccuTouch Product Manual for
hardware troubleshooting information. Contact Elo Technical Support if you
believe you have a hardware problem.
To check for interrupt contention with another device, turn off the computer and
remove the Interrupt (IRQ) jumper from the controller (the E271-2201 should not
have an interrupt jumpered). Power on and run BUSSTAT from DOS. If the
controller works, you probably have interrupt contention with another device. If
you are using the E281-4035 controller, it is also possible that the interrupt
specified during software setup did not match your jumper placement. Select
another interrupt and double-check your jumper placement.
With the E271-2201 controller, you may simply change the interrupt specified in
the Setup dialog of the Control Panel—it is not necessary to change jumpers
(except when in E271-141 emulation mode). See the AccuTouch Product Manual
for more information.
COMDUMP
COMDUMP.EXE allows you to test Elo serial controllers (E281-2310, E281{A}-
4002, E271-2210) from DOS. COMDUMP directly reads the system's serial ports
and displays any received data. This can determine if a problem is hardware or
software related.
COMDUMP can be used to determine the controller type, data mode and baud
rate of a controller. COMDUMP gives you a way to verify switch and jumper
settings if the controller is installed inside a cabinet and not easily accessible.
Also use COMDUMP to check that a controller/touchscreen/cable combination is
working correctly, which indicates that software driver setup is the problem.
To run COMDUMP, type the following at the DOS prompt:
COMDUMP <port 1 or 2> <baud rate>
The baud rate is optional. The default is 9600.
For example:
COMDUMP 2 2400