Elation Professional 575E User Manual

Page 44

Advertising
background image



Design Spot 575E™

©Elation Professional® 44

Design Spot 575E™

Gobo Rotation Er

(Gobo Rotation wheel 1- error) This message will appear after the reset of the fixture if the

yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the

stepping-motor is defective ( or its driving IC on the main PCB). The Gobo Rotation wheel 1

is not located in the default position after the reset.

Rotation gobo Er

(Rotating gobo wheel 2- error) This message will appear after the reset of the fixture if the

yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the

stepping-motor is defective ( or its driving IC on the main PCB). The Rotating gobo wheel 2

is not located in the default position after the reset.

Gobo Rotation Er

(Gobo Rotation wheel 2- error) This message will appear after the reset of the fixture if the

yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the

stepping-motor is defective ( or its driving IC on the main PCB). The Gobo Rotation wheel 2

is not located in the default position after the reset.

Prism Rotation Er

(Prism Rotation-wheel error) This message will appear after the reset of the fixture if the

yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the

stepping-motor is defective ( or its driving IC on the main PCB). The Prism Rotation -wheel is

not located in the default position after the reset.

Shutter, Strobe Er

(Shutter, Strobe-wheel error) This message will appear after the reset of the fixture if the

yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the

stepping-motor is defective (or its driving IC on the main PCB). The Shutter, Strobe -wheel is

not located in the default position after the reset.

Focus Er

(Focus error) This message will appear after the reset of the fixture if the yoke’s

Advertising