17.8 CALIBRATE TS (Cycle 460,

DIN/ISO: G460)

Cycle run

With Cycle 460 you can calibrate a triggering 3-D touch probe
automatically on an exact calibration sphere. You can do radius
calibration alone, or radius and length calibration.

1

Clamp the calibration sphere and check for potential collisions.

2

In the touch probe axis, position the touch probe over the
calibration sphere, and in the working plane, approximately over
the sphere center.

3

The first movement in the cycle is in the negative direction of the
touch probe axis.

4

Then the cycle determines the exact center of the sphere in the
touch probe axis.

Please note while programming:

Before programming, note the following

Pre-position the touch probe in the program so that it is
located approximately above the center of the calibration
sphere.