Event number

Display message, cause and corrective measures

9005

Changing grid param. not possible > Ensure DC supply
This error can have the following causes:

• The selected rotary switch setting for the country configuration is not

programmed.

• The parameters to be changed are protected.
• The DC voltage at the DC input is not sufficient to run the main CPU.

Corrective measures:

• Ensure that the country data set has been configured correctly.
• Enter the SMA Grid Guard code.
• Ensure that sufficient DC voltage is available (green LED is glowing or

flashing).

9007

Abort self-test
Error in the AC cabling.
Corrective measures:

• Ensure that the AC connection is correct (see operating manual of the

inverter).

4 Troubleshooting

SMA Solar Technology AG

Service Manual

STP15-17TL-10-SG-en-10