Welcome, Box contents, Mobile device compatibility – iHealth Lite User Manual

Page 5: Companion mobile app, Access ihealth cloud, Using the ihealth wireless scale lite, Scale handling & usage, Software updates, Software update troubleshooting, Product specifications

Advertising
background image

WELCOME

Congratulations on your new iHealth Wireless Scale Lite with
Bluetooth® 4.0 low-energy technology. This Scale tracks your weight
and BMI and, along with the free companion “iHealth MyVitals” app,
can help you stay motivated and on track for your weight goals.

BOX CONTENTS

Your iHealth Wireless Scale Lite package contains:

• 1 iHealth Wireless Scale Lite
• 4 AAA batteries, not installed
• 1 Quick Start Guide
• 1 User Manual

MOBILE DEVICE COMPATIBILITY

The iHealth Wireless Scale Lite works with the following iOS version
5.0 or higher devices:

• iPhone 4S +
• iPad mini
• iPad (3rd generation) +
• iPod touch (5th generation) +

COMPANION MOBILE APP

Scan the QR code and download the free "iHealth MyVitals"
companion app or directly download the "iHealth MyVitals" app
from the App Store. Follow the on-screen instructions to register
and set up your iHealth ID.

ACCESS IHEALTH CLOUD

Upon setting up your iHealth ID, you will also have access to a free,
secure iHealth cloud account. Go to www.ihealthlabs.com, then
click on “Sign In” to access your cloud account from PC or Mac using
your iHealth ID.

USING THE IHEALTH WIRELESS SCALE LITE

1. Install the Batteries

Open the battery compartment on the bottom of the Scale and
install the batteries.

2. First-time Use

For your first weigh-in, follow these steps to ensure the Scale
and the app are connected correctly and to synchronize the
date and time stamp for your next weigh-ins.
Œ

Enable the Bluetooth on your mobile device (Settings->Blue-

tooth->On).



Tap the Scale to turn it on. The Bluetooth icon on the Scale will

begin to flash.

Ž

Launch the app to initiate the connection. The Bluetooth icon

will light up and stop flashing when a successful connection is
established. The Scale is now connected and ready for your
weigh-in.

3. Your Next Weigh-in

Subsequent daily weigh-ins can be taken without being
connected to your mobile device, as your weight data is stored
in the Scale and uploaded to the app upon your next connec-
tion. Real-time weight results are viewable in the app if the Scale
is connected to your mobile device and the app is running when
your weigh-in occurs. The Scale can store up to 200 weight
measurements. When the memory is full, any new measure-
ments will overwrite the oldest ones.

SCALE HANDLING & USAGE

• The iHealth Wireless Scale Lite can measure weights up to 400 lb.
• For best results, the Scale should be used on a flat, hard surface.
Soft surfaces such as carpeting or rugs may affect the accuracy of
your reading.
• The iHealth Wireless Scale Lite has an automatic shutdown
feature to conserve battery power. The following scenarios will
cause the Scale to go into automatic shutdown mode:

º One minute has passed after completion of successful

weigh-in.
º The battery level is too low to capture an accurate weight
reading.

SOFTWARE UPDATES

From time to time, the Scale's software is updated to enhance
performance. When a software update is available, a notification
message will appear in the app. Complete the following steps to
install the update:

Œ

Follow steps 1-3 in the "First-time Use" section.



You will see a notification message in the app asking for

permission to proceed. Select "Yes".
Ž

The update will begin to download. You will see a cursor on the

scale display moving from left to right. The scale will display "0.0"
when the update is complete.

Software Update Troubleshooting

If the software update fails for any reason, you might experience
one of the following:

1. An error message reading “Er 10” appears in the display area. In

this case, the Scale software will automatically revert to factory
settings. The Scale will count up to 100 and then back to 0.0. This
step requires no user action. When the Scale has finished
counting down to 0.0, repeat Steps 1-2 above to restart the
software update.

2. The count up from 1 to 100 freezes and stops progressing. Re-

start the Scale by pressing the “Set” key on the back of the Scale
next to the battery compartment and hold it for 8 seconds.

PRODUCT SPECIFICATIONS

1. Product name: iHealth Wireless Scale Lite
2. Model: HS4
3. Classification: Internally powered
4. Machine dimensions: 13.8" x 13.8" x 1.1" (350 mm × 350 mm ×

28.5 mm)

5. Weight: Approximately 5.5 lb (2500 g)
6. Measuring method: Automatic full electronic measurement
7. Power: 4×1.5V AAA batteries

Battery life: Approximately 3 months with twice daily usage

8. Measurement range:

Body Weight: 11 lb~400 lb / 5 kg~180 kg

9. Accuracy:

Body Weight: ±1.1 lb / 0.5 kg (11 lb~110 lb / 5 kg~50 kg);

±1% (110 lb~400 lb / 50 kg~180 kg);

10. Operating temperature: 41°F~104°F (5°C~40°C)
11. Operating humidity: 20~85% RH
12. Environmental pressure for operation: 86~106 kPa
13. Storage and transport temperature: -4°F~131°F (-20°C~55°C)
14. Storage and transport humidity: ≤ 90% RH
15. Environmental pressure for storage: 50~106 kPa

Note: These specifications are subject to change without notice.

SAFETY INFORMATION

Read all of the information in the User Manual and any other
liter-ature in the box before operating the unit.

1. Please stand on the Scale, keeping as still as possible, until the

result appears on the display.

2. Do not stand on the edge of Scale, as you may fall over or

influence the accuracy of the measurement.

3. Do not use the Scale on a tiled or wet floor, as this may result

in a fall.

4. Make sure the surface of the Scale is clean and dry before

you step onto it, to prevent any slippage.

5. Treat your Scale with care. Do not drop it or jump on it. The

Scale is designed to be stood on; misuse or abuse may break the
electronic sensors, cause injury, or result in inaccurate measure-
ments.

6. Never immerse the Scale in water. Clean the surface with a

damp cloth.

7. Do not use the Scale on an uneven floor or soft surfaces such as

carpets or rugs while weighing, as doing so may result in
unreliable measurements.

8. To avoid damage as a result of battery leakage, remove the

batteries if the Scale is not going to be used for 3 months or
more.

9. Do not use or store near strong magnetic fields, such as micro-

wave ovens.

10. The Scale may not perform accurately if it is stored or used

outside the specified temperature and humidity ranges quoted
above under “Specifications.”

11. This device complies with part 15 of the FCC Rules. Operation

is subject to the following two conditions:

Œ

This device may not cause harmful interference, and



This device must accept any interference received, including

interference that may cause undesired operation.

12. Changes or modifications not expressly approved by iHealth

Lab Inc. invalidate the user’s warranty for this equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interfer-
ence to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:

—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and

receiver.

—Connect the equipment to an outlet on a circuit different

from that to which the receiver is connected.

—Consult the dealer or an experienced radio/TV technician
for help.

13. This device complies with Industry Canada license-exempt

RSS standard(s). Operation is subject to the following two
conditions:

Œ

This device may not cause interference, and



This device must accept any interference, including inter-

ference that may cause undesired operation of the device.

14. Under Industry Canada regulations, this radio transmitter

may only operate using an antenna of a type and maximum (or
lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna
type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.

TROUBLESHOOTING

AT&T

7:28 AM

98%

AT&T

7:28 AM

98%

4