8 jumper switch settings, Setting for jp1 – Epson S5U1C17801T1100 User Manual

Page 28

Advertising
background image

8 JUMPER SWITCH SETTINGS

22

EPSON

S5U1C17801T1100 HARDWARE MANUAL

(SOFTWARE EVALUATION TOOL FOR S1C17801)

8 Jumper Switch Settings

Three jumper switches are installed on the surface of the SVT17801. Each function is as follows:

Setting for JP1

JP1 can be used to select Wakeup Enable or Disable as shown in the following. 1-2 on JP1 must be shorted to select
Wakeup Enable. Wakeup Enable can be controlled by the Wakeup pin on the S1C17801 or on-board power switch.
For details, see the description of RTC control circuit in Chapter 10. Shorting 2-3 on JP1 disables the Wakeup func-
tion.
Factory default setting for JP1 is Wakeup Enable.

To 3.3V regulator

JP1

JP1

JP1

ENABLE W

AKEUP

DISABLE W

AKEUP

To POWER SW

To WAKEUP pin

1

2

2

3

DIC-149-3P

R59
10K

Q11

UNR5213

1

U24
SN74LVC1G98DCKR

3

C49

0.1µF

5

6

4

+5V

G

G

V

Fig. 8.1.1 JP1 Related Circuit

Advertising