Timer control, Clear meter bridge lcd screen, Logitek – Logitek Electronic Systems Artisan User Manual

Page 61

Advertising
background image

Logitek

Appendix E
Additional Protocol Commands

Timer Control

Used to control the Artisan timer displays. (v2.0 and later)

Seq

Byte

Description

Notes

1

<02>

Start byte

2

<06>

<15>

Bytes to follow
Bytes to follow

<06> bytes for Timer Command
<15> bytes for Timer Reset (includes ASCII text label)

3

<AE>

Command = Set Effect

4

<d#>

Device Number

Device Number of Meter Bridge in hex (53 = Port 1)

5

<40>

Type = Timer Control

6

<t#>

Timer Number

<01> = Timer 1 <02> = Timer 2

7

<cm>

Command Byte

See table below

8

<dt>

Data Byte / ASCII Byte 1 See table below

9-23

<dt>

ASCII Data Bytes 2-16

For Command <03> and <04>, bytes 8-23 are the 16 character device name printed
inside the timer as 2 x8 character strings. For other Commands, these bytes are omitted.

Command Byte

Data Byte

<01> = Run

<00> = Stop

<01> = Run

<02> = Auto Reset

<00> = Off

<01> = On

<03> = Fader Reset

16 character source name (only works in Auto Mode)

<04> = Manual Reset

16 character source name (working in Auto & Manual modes)

<05> = Direction

<00> = Up

<01> = Down

<06> = Keypad Digit

0 to 9 for each keypad digit – 1 command per digit press

The follow example will set Timer #1 into run mode:

02 06 AE 53 40 01 01 01

Clear Meter Bridge LCD Screen

Used to clear an LCD screen on the Meter Bridge. (v2.0 and later)

Seq

Byte

Description

Notes

1

<02>

Start byte

2

<04>

Bytes to follow

3

<AE>

Command = Set Effect

4

<d#>

Device Number

Device Number of Meter Bridge in hex (53 = Port 1)

5

<32>

Type = Clear LCD

6

<dt>

Data Byte = LCD #

<01> to <06> = LCD screen number, from left to right

This is used where it is necessary to clear all text & graphics from a Meter Bridge LCD screen.

The following example will clear LCD #1 on an Artisan Wide Meter Bridge:

02 04 AE 53 32 01