Timer control, Clear meter bridge lcd screen, Logitek – Logitek Electronic Systems Artisan User Manual
Page 61

Logitek
Appendix E
Additional Protocol Commands
Timer Control
Used to control the Artisan timer displays. (v2.0 and later)
Seq
Byte
Description
Notes
1
<02>
Start byte
2
<06>
<15>
Bytes to follow
Bytes to follow
<06> bytes for Timer Command
<15> bytes for Timer Reset (includes ASCII text label)
3
<AE>
Command = Set Effect
4
<d#>
Device Number
Device Number of Meter Bridge in hex (53 = Port 1)
5
<40>
Type = Timer Control
6
<t#>
Timer Number
<01> = Timer 1 <02> = Timer 2
7
<cm>
Command Byte
See table below
8
<dt>
Data Byte / ASCII Byte 1 See table below
9-23
<dt>
ASCII Data Bytes 2-16
For Command <03> and <04>, bytes 8-23 are the 16 character device name printed
inside the timer as 2 x8 character strings. For other Commands, these bytes are omitted.
Command Byte
Data Byte
<01> = Run
<00> = Stop
<01> = Run
<02> = Auto Reset
<00> = Off
<01> = On
<03> = Fader Reset
16 character source name (only works in Auto Mode)
<04> = Manual Reset
16 character source name (working in Auto & Manual modes)
<05> = Direction
<00> = Up
<01> = Down
<06> = Keypad Digit
0 to 9 for each keypad digit – 1 command per digit press
The follow example will set Timer #1 into run mode:
02 06 AE 53 40 01 01 01
Clear Meter Bridge LCD Screen
Used to clear an LCD screen on the Meter Bridge. (v2.0 and later)
Seq
Byte
Description
Notes
1
<02>
Start byte
2
<04>
Bytes to follow
3
<AE>
Command = Set Effect
4
<d#>
Device Number
Device Number of Meter Bridge in hex (53 = Port 1)
5
<32>
Type = Clear LCD
6
<dt>
Data Byte = LCD #
<01> to <06> = LCD screen number, from left to right
This is used where it is necessary to clear all text & graphics from a Meter Bridge LCD screen.
The following example will clear LCD #1 on an Artisan Wide Meter Bridge:
02 04 AE 53 32 01
Logitek Artisan Reference Manual
59