Specifi cations

1. Model:

HA-D32DCHG

2. Charging:

Charging Method:

Constant voltage (with current limiter)

(when one Handheld Terminal has been mounted)

Charge Period:

Approx. 2 hours (1 standard battery pack, normal temperature)

Approx. 4 hours (1 large-capacity battery pack, normal temperature)

When charging two battery packs:

Approx. 3.5 hours (2 standard battery packs, normal temperature)

Approx. 7 hours (2 large-capacity battery packs, normal temperature)

3. Power Supply:

Power Source:

AD-S42120C-N5/AD-S42120B

Consumption Current:

Approximately 450mA

4. AC Adaptor:

Model: AD-S42120C-N5/AD-S42120B
Input:

100V to 240V AC 50/60Hz 1.2A

Output:

12V DC 3.5A

Consumption Current:

Approximately 450mA

5. Operating Environment:

Temperature:

Approximately 0°C to 40°C (32°F to 104°F)

Humidity:

30% to 80% RH (non-condensation)

6. Dimensions and Weight:

Dimensions: Approximately

110(W)

× 104(D) × 46(H) mm

(4

5

16

"W

× 4

1

8

"D

× 1

13

16

"H)

Weight:

Approximately 195g (6.9oz)