GT-1000 Technical Data
This appendix provides technical information that is relevant to
software control of the EPSON GT-1000 color image scanner. For
further details about this particular scanner model, see the
GT-1000 user’s guide.
Physical Characteristics
Function level:
B2
Maximum reading area:
74mm
×
105mm
Effective pixels:
592
×
840 dots at 200 dpi, 100%
Standard interface:
RS-232C serial
Bi-directional parallel
Optional interface:
(not available)
Serial interface protocols:
Transfer rate:
2400, 4800, 9600, and 19200 bps
Stop bit:
2 bits and 1 bit
Parity check:
None
Error Indications
Scanner errors are displayed on the control panel by a
combination of the ERROR and READY lights as shown below.
Error name
ERROR light
READY light
Command Error
On
On
Interface Error
Flashes
Off
Fatal Error
Flashes
Flashes
B-2