RPBASIC-52 PROGRAMMING GUIDE

2-11

CBY

Syntax:

C B Y (expr)
Where: expr = address from 0 to 65535

Function:

Reads internal program code

Mode:

Comm and, run

Use:

P R I N T C B Y (1 0 0 0H )

Cards:

All

D E S C R IP T I ON

The C BY instruc tion rea ds data from p rogram mem ory spa ce in th e 8052 . expr must evalu ate to a valid
integer address of 00H through 0FFFFH (65535). Code memory is read-only.

RELATED

D B Y , X B Y , P E E K , P O K E

E R R O R

B A D A R G U M E N T expr must be a v alid integer (0 through 65535).

EXAMPLE

10 FOR N=0 TO 10
20 PRINT CBY(N),
30 NEXT

>RUN
97 203 255 210 22 50 2 39 110 255 255