Avago Technologies AcceleRAID 150 User Manual

Page 39

Advertising
background image

Installation

Manual No. 775020

2-25

8. AcceleRAID

150 Termination (SISL)

Check to confirm that all drive channels are properly terminated as
shown in Figure 2-22. The AcceleRAID 150 is equipped with
automatic SCSI termination circuitry for the SCSI channel that resides
on the AcceleRAID controller. If the controller is at the end of the SCSI
bus, it automatically enables on-board termination.

If all the SCSI devices on a channel are connected either to the internal
connector or to the external connector, the end of the SCSI bus farthest
from the controller must have a terminator installed. In this case, the
controller automatically enables on-board termination.

If some SCSI devices on the channel are connected to the internal
connector, and
some are connected to the external connector, the
two ends of the SCSI bus farthest from the controller must each be
terminated. In this case, the controller automatically disables on-board
termination. See Figure 2-22 for an example of an internal / external
drive configuration. Notice the terminator “T” symbol indicating
termination at the farthest bus ends. External drive cabinets usually
have termination built into the end of the SCSI bus.

Note

The illustrated internal and external connectors are
both on the same channel.

It is better to terminate the ends of the SCSI bus itself
than it is to terminate the end devices on the bus. This
allows hot swap devices to be added or removed from
the SCSI bus without affecting termination.

Figure 2-22. Termination with Internal / External Drive Configuration

T

T