22 regulatory compliance – Endura RADISYS KP915GV User Manual
Page 34
KP915GV Product Manual
34
2.22 Regulatory
Compliance
Table 6. Regulatory Testing*
Characteristic
State
Value
ESD
Operating
Designed and tested to pass (not certified):
To IEC 1000-4-2 / EN61000-4-2: 1995
4kV direct contact, performance criteria B
6kV direct contact, performance criteria C
4kV air discharge, performance criteria B
8kV air discharge, performance criteria C
Fast transient/burst
Operating
Designed and tested to pass (not certified):
IEC 1000-4-4/EN61000-4-4: 1995, performance criteria B
Surge voltages
Operating
Designed and tested to pass (not certified):
IEC 1000-4-5 / EN61000-4-5: 1995, performance criteria B
Conducted Operating
Designed
and
tested to pass (not certified):
IEC 1000-4-6 / EN61000-4-6: 1995, performance criteria B
Radiated emissions Operating
Designed and tested to pass (not certified):
CISPR 22: 1998, Class B
EN55022, EN55024
FCC Class B
Radiated immunity
Conducted
immunity
Operating
Operating
EN61000-4-3, performance criteria A
EN61000-4-6, performance criteria A
AC power dips and
interrupts
Operating
EN61000-4-11performance criteria B and C
Safety
UL60950-1, CSA60950-1, EN60950-1, IEC60950-1
CB report to IEC60950-1
Recognized component to UL60950-1
UL60950-1 approval will become accessory listing in Q405
* EMC and immunity testing performed in an example standard desktop chassis.