2.22 Regulatory

Compliance

Table 6. Regulatory Testing*

Characteristic

State

Value

ESD

Operating

Designed and tested to pass (not certified):

To IEC 1000-4-2 / EN61000-4-2: 1995

4kV direct contact, performance criteria B
6kV direct contact, performance criteria C
4kV air discharge, performance criteria B
8kV air discharge, performance criteria C

Fast transient/burst

Operating

Designed and tested to pass (not certified):

IEC 1000-4-4/EN61000-4-4: 1995, performance criteria B

Surge voltages

Operating

Designed and tested to pass (not certified):

IEC 1000-4-5 / EN61000-4-5: 1995, performance criteria B

Conducted Operating

Designed

and

tested to pass (not certified):

IEC 1000-4-6 / EN61000-4-6: 1995, performance criteria B

Radiated emissions Operating

Designed and tested to pass (not certified):

CISPR 22: 1998, Class B

EN55022, EN55024

FCC Class B

Radiated immunity

Conducted
immunity

Operating

Operating

EN61000-4-3, performance criteria A

EN61000-4-6, performance criteria A

AC power dips and
interrupts

Operating

EN61000-4-11performance criteria B and C

Safety

UL60950-1, CSA60950-1, EN60950-1, IEC60950-1

CB report to IEC60950-1

Recognized component to UL60950-1

UL60950-1 approval will become accessory listing in Q405

* EMC and immunity testing performed in an example standard desktop chassis.