EDELBROCK AIR CLEANER

Catalog #s 1207, 1208, 1209, 1221, 1222, 1235, 1236, 4207,

4210, 4220, 4221, 4222, 4223, 4224, 4235, 4236, 4237, 4239

INSTALLATION INSTRUCTIONS

Please study these instructions carefully before installing your new Air Cleaner Assemblies. If you have any questions or problems, do not
hesitate to contact our Technical Hotline at: (800) 416-8628 from 7:00 am to 5:00 pm, Monday through Friday, Pacific Standard Time
or e-mail us at: [email protected].

DESCRIPTION: Edelbrock Air Cleaner Assemblies - Due to the many different applications of the Edelbrock air filters, some modifications
maybe required.

INSTALLATION INSTRUCTIONS:

1.

Install suitable air horn gasket and carburetor stud (not supplied) on carburetor(s) and
place air cleaner base over carburetor.

2.

For single carb models with dual carb tops, thread the special bracket on the carb stud
until the two studs protrude through the top of the air cleaner by about 1/2". Bracket
must be positioned to clear carburetor choke linkage and choke plate.

3.

Install filter and air cleaner lid, checking for clearance between the carb stud and lid.
Trim carb stud, if necessary. For carburetors with tall bowl vent tubes, it may be
necessary to purchase Edelbrock air cleaner spacer #8092. Vent tube to air cleaner
clearance should be no less than 1/8".

Note: To prevent possible hood damage, check for proper hood clearance using clay
cones as seen in Figure #1. Don’t shut the hood without checking clearance first!

CRANKCASE VENTILATION:

Note: Some air cleaner kits include the crankcase ventilation adapter, that mounts to the lower
side of the air cleaner per the recess seen in Figure #2 (Crankcase ventilation adapter #1205).
Other kits may not be applicable.

1.

If you wish to use the crankcase ventilation hose fitting, drill two ¼" bolt holes (A) in the
recessed area at the rear of the air cleaner base, then drill a few ¼" holes (B) in the larger
recess window to allow the fitting to breath (See Figure #2). Bolt the fitting to the base
with the ¼" nuts, bolts, and washers. Be sure to de-burr drilled holes.

2.

Check for clearance between linkage and ventilation hose and rotate base as necessary.

MAINTENANCE:
Some air cleaner assemblies have a pre-oiled gauze element, that can be cleaned and re-oiled as needed to improve its air flow. Simply
wash the element in hot soapy water and allow to dry, then apply a light aerosol oil. Replacement pre-oiled gauze elements (Edelbrock
#1220) are available through your dealer. Replacement knurled nuts for Elite Series Oval Air Cleaners are available as Edelbrock #4219.
The gauze elements are dark in color when shipped and the paper elements are white in color. Do not attempt to wash the paper type
elements.

PLEASE complete and mail your warranty card. Be sure to write the model number of this product in the "Part #____" space. THANK
YOU.

HOOD CLEARANCE

FORW

ARD

CLAY CONES

Figure #1

Figure #2