The rangetop must be connected to a regulated gas
supply. The supply line must be equipped with an approved
external gas shut-off valve located near the rangetop in an
accessible location. Do not block access to the shut-off
valve. Refer to the illustration below.

A gas supply of 3/4"

(19)

ID line must be provided to the

rangetop. If local codes permit, a certified, 3'

(.9 m)

long,

1/2"

(13)

or 3/4"

(19)

ID flexible metal appliance connector is

recommended to connect the units 1/2" NPT female inlet to
the gas supply line. Pipe joint compounds suitable for use
with natural or LP gas should be used.

The appliance and its shut-off valve must be disconnected
from the gas supply piping system during any pressure
testing of the system at test pressures in excess of .5 psi

(3.5 kPa)

. The appliance must be isolated from the gas

supply piping system by closing its individual manual shut-
off valve during any pressure testing of the system at test
pressures equal to or less than .5 psi

(3.5 kPa)

.

Wolf natural gas rangetops will function up to 10,250'

(3124 m)

in altitude without adjustment and LP gas ran-

getops up to 8,600'

(2621 m)

. If the installation exceeds

these elevations, contact your authorized Wolf dealer for
a high altitude conversion kit.

Gas Supply

Installation must comply with local codes or, in the
absence of local codes, with the National Fuel Gas Code.

Locate the gas supply within the shaded area shown in the
illustration on the following page.

The rangetop is equipped for use with natural or liquid
propane (LP) gas. The product rating plate has information
on the type of gas that should be used. For rating plate
location, refer to the illustration below. If this information
does not agree with the type of gas available, check with
the local gas supplier. The gas pressure regulator is built
into the unit.

GAS REQUIREMENTS

NATURAL GAS

WC

Supply Pressure

5"

(12.5 mb)

Min Line Pressure

7"

(17.5 mb)

Max Regulator Pressure

14"

(34.9 mb)

, .5 psi

(3.5 kPa)

LP GAS

WC

Supply Pressure

10"

(25 mb)

Min Line Pressure

11"

(27.4 mb)

Max Regulator Pressure

14"

(34.9 mb)

, .5 psi

(3.5 kPa)

SHUT-OFF VALVE

OPEN POSITION

GAS SUPPLY

TO APPLIANCE


Gas shut-off valve


Rating plate location

RATING PLATE