Hampton H200 Cast Freestanding Woodstove

9

INSTALLATION

Residential Installation “C” Vent (Single Wall)

Unit (with Heat Shield)

From Unit From

From Flue Center-Line

Corner

A

B

C

D E

F

H200

17" (431 mm) 15" (381 mm) 13" (330 mm) 29" (737 mm) 17-1/8"(435 mm) 19-7/8" (505mm)

Residential Close Clearance (To be installed with required pipe components)

When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling
level.

Unit (with Heat Shield)

From Unit From

From Flue Center-Line

Corner

A

B

C D

E

F

H200

15" (381 mm) 10" (254 mm) 9" (228 mm) 27" (686 mm) 12-1/8" (308 mm) 15-7/8" (403mm)

Mobile Home Close Clearance (To be installed with required pipe components)

"C" Vent single wall pipe is not approved for Mobile Home installations (refer to Mobile Home Instructions).

Unit (with Heat Shield)

From Unit From

From Flue Center-Line

Corner

A

B

C

D

E

F

H200 15" (381mm) 10" (254 mm) 9" (228mm) 27" (686mm) 12-1/8" (308mm) 15-7/8" (381mm)

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Please read the section below carefully. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the
rear heat shield to a back wall.

Clearances may only be reduced by means approved by the regulatory authority.

NOTE: Be aware that local Codes and Regulations may override some clearances listed in this manual.

Check with your local inspector.