Operating your humidifier, He365a, He365b – Honeywell HE365B User Manual

Page 3: He365a,b powered flow-through humidifier

Advertising
background image

HE365A,B POWERED FLOW-THROUGH HUMIDIFIER

3

69-1427-3

OPERATING YOUR HUMIDIFIER

HE365A

Your Enviracaire Elite™ HE365A Humidifier from

Honeywell is controlled by the H8908B Convertible

Humidity Control. The convertible humidity control is

installed either on an interior wall in the living area, or

on the return air duct. Choose the humidity control

setting using the combination relative humidity/

outdoor temperature setting scale on your humidity

control dial. Match the dial setting to the outdoor

temperature for optimizing the humidity level while

reducing the moisture condensation on your windows.

The table below can also be used to adjust the

humidity control to the recommended setting.

NOTE: As the outside temperature drops, the recommended humidity control setting

is lowered to accommodate for effects of dewpoint. These settings should

reduce the accumulation of moisture and ice on your windows and in other

areas of your home.

Some indoor activities such as cooking, showering and clothes drying can cause

excessive levels of humidity and start the accumulation of moisture on your windows.

NOTE: If this condition persists for more than a few hours, set the humidity control to

the lowest setting to turn off the humidifier. If the condition does not improve,

ventilate your home to remove the moisture.

HE365B

Your Enviracaire Elite™ HE365B Humidifier is controlled

by the Honeywell H1008 Automatic Humidity Control

with HumidCalc+™. The automatic humidity control is

mounted in the return air duct where it can be exposed

to the air stream of the return air.

At Outside

Temperature

Recommended

Control Setting

At Outside

Temperature

Recommended

Control Setting

-20°F (-29°C)

15

+10°F (-12°C)

30

-10°F (-23°C)

20

+20°F (-7°C)

35

0°F (-18°C)

25

Above 20°F (-7°C)

40

Humidity Control

Régulateur d'humidité

-20

°

F

-10

°

F

0

°

F

+10

°

F

+20

°

F

Over 20

°

F

15%
20%

25%
30%

35%
40%

HUMIDITY
SETTING

OUTDOOR

TEMPERATURE

-30

°

C

-25

°

C

-20

°

C

-10

°

C

-5

°

C

Over 0

°

C

M14694

M12817

H1008A

Advertising
This manual is related to the following products: