background image

Server component identification

17

System LED
and color

Internal
Health LED
color

Status

Processor
failure, both
sockets
(Amber)

Red

Processor types are mismatched.

PPM failure
(Amber)

Red

PPM has failed.

DIMM failure,
slot X (Amber)

Red •

DIMM in slot X has failed.

DIMM in slot X is an unsupported type, and no valid memory

exists in another bank.

Amber •

DIMM in slot X has reached single-bit correctable error

threshold.

DIMM in slot X is in a pre-failure condition.

DIMM in slot X is an unsupported type, but valid memory exists

in another bank.

DIMM failure, all
slots in one
bank (Amber)

Red

No valid or usable memory is installed in the system.

Overtemperatur
e (Amber)

Amber

The health driver has detected a cautionary temperature level.

Red

The server has detected a hardware critical temperature level.

Riser interlock
(Amber)

Red

The PCI riser board assembly is not seated.

Online spare
memory
(Amber)

Amber Bank

X failed over to the online spare memory bank.

Power
converter
module
interlock
(Amber)

Red

The power converter module is not seated.

Fan module
(Amber)

Amber

A redundant fan has failed.

Fan module
(Red)

Red

The minimum fan requirements are not being met in one or more
of the fan modules. One or more fans have failed or are missing.