Battery recycling – Hoover HandVac User Manual

Page 7

Advertising
background image

7

Align filter frame with separator frame
and press edges together.

3-8

3-6

3-7

Replace filter/separator assembly into
collector cup.

If soiled, wipe motor/handle section with
a damp cloth.

Do not immerse in

water.

Reattach cup assembly to motor as
shown.

Hang cleaner back on wall bracket for
storage and recharging.

Battery recycling

Your cleaner contains nickel-cadmium
batteries.

When these batteries no longer
recharge, they must be removed from
the cleaner, recycled and disposed of
properly in accordance with state
laws as described in Item 3-14.

If you want to have a new battery pack
installed, contact your Hoover Factory
Service Center.

The following instructions are for dis-
assembly purposes ONLY.

3-9

How to remove battery
pack

Note: Do not remove the batteries to
recharge them.

Follow the instructions

for charging the cleaner.

The batteries

should only be removed if they no
longer recharge and you plan to dis-
pose of the cleaner.

Press latch and remove motor/handle
section of the cleaner from collector cup.

Cut data label (E) along seam on bottom
of motor/handle.

E

3-10

Unscrew the 4 Phillips head screws
on motor/handle section.

3-11

Separate motor/handle section halves.
(The motor assembly will remain in one
half of the housing.)

3-12

Pull motor assembly (F) from housing
(H). Remove only the tape that holds the
batteries (G) in place in the holder.

Do not remove label from the battery
pack.

F

G

H

3-13

Slide battery pack out of holders.

Disconnect the two wires from battery
terminals.

Dispose of battery pack in accordance
with your local and state laws.

(See fol-

lowing page.)

Continued