V ~ a, Symbology – Harbor Freight Tools 94029 User Manual

Page 9

Advertising
background image

SKU 94029

For technical questions, please call 1-800-444-3353.

Page 9

electrician before using it.

8.

Protect your extension cords from sharp objects, excessive heat, and damp or
wet areas.

SYMBOLOGY

V ~

A

xxxx/min.

FIGURE D

Double Insulated

Canadian Standards

Association

Underwriters

Laboratories, Inc.

Volts Alternating

Current

Amperes

No Load Revolutions

Per Minute (RPM)

FIGURE C

no

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120 VOLT)

NAMEPLATE

AMPERES

(At Full Load)

EXTENSION CORD LENGTH

25

FEET

50

FEET

75

FEET

100

FEET

150

FEET

0-2.0

18

18

18

18

16

2.1-3.4

18

18

18

16

14

3.5-5.0

18

18

16

14

12

5.1-7.0

18

16

14

12

12

7.1-12.0

18

14

12

10

-

12.1-16.0

14

12

10

-

-

16.1-20.0

12

10

-

-

-

*Based on limiting the line voltage drop

to five volts at 150% of the rated amperes.

Advertising