Assigning zones and issuing room names

33

Find the zoning plan.

Press and hold Installation
button on storey controller for
at least 2 seconds.
The LED illuminates. The
LED of zone 1 flashes red.
The storey controller is in in-
stallation mode and waits for
the signal from the setpoint
adjuster.

To assign the setpoint adjuster to another zone, press the
Installation button until the LED of the desired zone flashes
red.

Press the Send button of the setpoint adjuster.
The setpoint adjuster is assigned to zone 1.
The LED of the selected zone lights continuously red.

If no Hometronic Manager is installed, the storey controller
operates with a basic value of 20 °C. For information on how
the configuration is checked please refer to Page 40 .