Quickspecs – HP Z600 User Manual

Page 27

Advertising
background image

CPUs and Heatsinks

A torx driver (T15) is needed to remove the CPU heatsink(s) before the CPU can be removed.
CPU removal is tool-less

Power supply
diagnostic LED

Yes

Power Button

Yes

Power LED

Yes, blue (normal), red (fault)

Hard drive activity LED Yes, green

Internal speaker

Yes

System/Emergency
ROM Flash Recovery

Recovers corrupted system BIOS.

OS CD (Restore OS CD) Restores computer to its original factory shipping image; No recovery CDs will ship with Windows

XP, Vista or Linux - an ISO image will be available on an HD partition

ASF 2.0 support (Alert
Standard Format)

Industry-standard specification for network alerting in operating system-absent environments

Cooling Solutions

Air cooled forced convection

Power Supply Fans

2x -- 60mm x 25mm

CPU Heatsink Fan(s)

80mm x 15mm

Chassis Fans

Rear: 2x -- 92mm x 25mm
Front: 80mm x 25mm

Memory Fans

80mm x 25mm

Insight Diagnostics

HP Insight Diagnostics Offline Edition
The diagnostics utility enables you to perform testing and to view critical computer hardware and
software configuration information from various sources. This utility enables you to:

Run diagnostics
View the hardware configuration of the system

Key features and benefits
HP Insight Diagnostics simplifies the process of effectively identifying, diagnosing, and isolating
the hardware issues. In addition to robust management tools, service tools can be invaluable in
quickly resolving system problems. To streamline the service process and resolve problems
quickly, it is necessary to have the right information available at the time that a service call is
placed. The primary information requirement, which is also the one that provides the greatest
insight into potential system issues, is the configuration of the system. Insight Diagnostics helps
provide higher system availability. Typical uses of the Insight Diagnostics are:

Testing and diagnosing apparent hardware failures
Documenting system configurations for upgrade planning, standardization, inventory
tracking, disaster recovery, and maintenance
Sending configuration information to another location for more in-depth analysis

Access Panel Key Lock Yes, prevents removal of the access panel and all internal components including optical and

floppy drives

ACPI-Ready Hardware Advanced Configuration and Power Management Interface (ACPI).

Allows the system to wake from a low power mode.
Controls system power consumption, making it possible to place individual cards and
peripherals in a low-power or powered-off state without affecting other elements of the
system