Safety non contact switch ff-snc, Dimensions (mm/in) – Honeywell FF-SNC User Manual

Page 2

Advertising
background image

2

Safety Products for Machine Safeguarding -

© 2002 - 2004 Honeywell International Inc. All rights reserved.

W

22,5 / 0.88

75 / 2.95

H

84 / 3.30

74 / 2.91

D

119 / 4.68

119 / 4.68

FF-SNC200R2

FF-SNC1EXTFF-SNC400R2

FF-SNC400RE

(mm/in)

W

H

D

H

A1

DR

BL

DR

BL

DR

BL

A2

DR

BL

DR

BL BL

DR

GATE 4 GATE 5

GATE 3

GATE 1 GATE 2

Safety Non Contact Switch FF-SNC

• Complies with the requirements of the EN 954-1 for Category 3

equipment

• Meets applicable parts of ANSI/RIA/OSHA regulations

Dimensions in millimeters / inches, meters / feet, weights in kg / lbs

Features

Switch

Material

Sensing range

Minimum gap

Standard cable length

Temperature

Connection to the control unit

Sealing

Fixing

Control unit / extension module

Category

Supply voltage

Response time of the control unit

Power consumption (including sensors)

Temperature

Output

Output Contact Rating

Restart

Sealing

Mounting

LED indicators

Material

ABS (FF-SNC1SA❏❏

❏❏

❏❏

❏❏

❏❏PA-

) or Stainless Steel 316 and Resin filled (FF-SNC1SA❏❏

❏❏

❏❏

❏❏

❏❏PS)

5 mm - 7 mm / 0.20 in - 0.27 in ON • 8 mm - 12 mm / 0.32 in - 0.47 in OFF

allowable misalignment: ±4mm / ±1/6 in

1 mm

Prewired 3 m / 9.84 ft or 5 m/16.4 ft (ABS only) - M8 plug: 5 mm/16.4 ft (ABS only)

Operating: -10 °C to +55 °C/14 °F to 131 °F • Storage: -20 °C to +60 °C/-4 °F to 140 °F

Max. cable length: 100 m / 328 ft

IP 67 prewired or M8 plug

2 x (M4 x 20 mm) Tamper proof screws (supplied with the product)

Category 3 according to EN 954-1

24 Vdc/Vac ±15 % • 110 Vac ±15 % (FF-SNC400RE only)

15 ms (with or without extension module)

6 VA (with or without ext. module): FF-SNC400 • 3 VA (with or without ext. module) : FF-SNC200

Operating : -10 °C to + 55 °C / 14 °F to 131 °F • Storage: -20 °C to 60 °C / -4 °F to 140 °F

2 NO + 1 NC relay contact

Max.: 4 A / 230 Vac; 2 A / 24 Vdc (Res.) @Cos = 1 • Min.: 10 V / 10 mA

Manual or automatic

IP 40 Housing, Terminals IP 20

35 mm / 1.37 in DIN rail

FF-SNC200R2 control unit: Power, Run and 2 guard status indicators

FF-SNC400RE control unit: 4 guard status indicators and deselect indicators

Polycarbonate, red

UL

C

US

STED

LI

®

CATEGORY 3

per EN 954-1

Suitable for interfaces

up to

Dimensions (mm/in)

Prewired

M8 plug

M4 x 20 mmTorx screws are supplied with the switches.

SIDE

3 / 0.11

ш 8,1 / 0.32

ш 4,2 / 0.16

6,4 / 0.25

22 / 0.86

SIDE

22 / 0.86

3 / 0.11

ø 8,1 / 0.32

6 / 0.23

a / 2

a / 2

ø 4,2 / 0.16

6,4 / 0.25

b

a

c

b

a

c

ABS

SS316

52 / 2.04

a

b

c

53 / 2.8

28 / 1.10

29 / 1.14

14 / 0.55

13.5 / 0.53

Advertising