Service & maintenance – Harman Stove Company HARMAN Super Magnum Coal Stoker Stove User Manual

Page 24

Advertising
background image

24

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal!

3-90-02702R6_03/13

A. Shut-down Procedure

The best way to shut down the appliance is to simply let it

run out of fuel, and shut down naturally as the temperature

cools. This method is highly recommended for the end of

season shut-down.
To shut-down otherwise, turn the mode selector to "OFF'

verify by ensuring that the Status light goes out. The shut-

down protocol of the circuit board will safely allow the fire

to go out.

B. Quick Reference Maintenance Chart

Cleaning or Inspection

Frequency

Daily Weekly Monthly Yearly

Area beneath fire grates

After each ton burned

OR

X

Ash removal

Whenever filling the unit hopper

OR

X

Combustion blower

More frequently depending on

surroundings

OR

X

Distribution air filter

Replace as needed

OR

X

Distribution blower

More frequently depending on

surroundings

OR

X

Door latch inspection

Prior to heating season

OR

X

Fines tray

Depending on fuel quality

OR

X

Firebox / thorough cleaning

End of heating season

OR

X

Glass

When veiw of fire becomes

obstructed

OR

X

Heat exchanger / Chain scraper

Whenever filling the unit hopper

OR

X

Hopper

Whenever adding fuel

OR

X

Venting system

More frequently depending on fuel

quality and quantity

OR

X

Soot Formation and Need For Removal- When coal is

burned, the products of combustion combine with moisture

to form a soot residue which accumulates on the flue lining.

When ignited, this soot makes an extremely hot fire. The

chimney and chimney connector should be inspected at

least once every two months during the heating season

to determine if a soot buildup has occurred. If soot has

accumulated, it should be removed to reduce the risk of a

chimney fire.
If you experiance a chimney fire; Remove all burning fuel

from the grate by scraping it into the ash pan. Move the ash

pan safely outside the home and place it on the ground,

well away from any combustibles. Turn the control to "Off"

and notify the fire department. Do not operate the appliance

until the chimney and connector have been inspected and

approved by a chimney professional.

10

Service & Maintenance

Advertising