Maximum storage capacity, Eventlogging, Access test results – Honeywell MicroDock II User Manual

Page 13

Advertising
background image

11

MicroDock II

Automatic Datalog Download (GasAlertMicroClip and GasAlertMax XT docking module only)

Successful Data Transfer: The PASS LED lights green on the
docking module and Pass displays on the base station LCD.
From the LCD, press C Pass to return to normal operation.

Unsuccessful Data Transfer: The FAIL LED lights red on the
docking module. Attempt to transfer the data again. If the sec-
ond data transfer is unsuccessful, ensure the detector is acti-
vated. If the problem persists, contact

BW Technologies by

Honeywell

.

3.

To transfer the datalogs to Fleet Manager II, refer to
the Importing Data into Fleet Manager II in the Fleet
Manager II
Technical Reference Guide.

4.

To view the data that was transferred to the MMC,
refer to Viewing Data in Fleet Manager II in the Fleet
Manager II Technical Reference Guide
.

Maximum Storage Capacity

When the maximum storage is reached, the base station
replaces the oldest datalogs with the new datalogs.

Automatic Datalog Download

(GasAlertMicroClip

and GasAlertMax XT docking module only)

The Automatic Datalog Download option is enabled/disabled
through Fleet Manager II. If the option is enabled, datalogs are
transferred every time a bump test or calibration is performed.

After performing a bump test or calibration on the GasAlertMi-
croClip and GasAlertMax XT docking module, the PASS LED
lights green. The DATA TRANSFER RUN LED then lights yel-
low as the transfer begins.

a

Caution

Do not remove the GasAlertMicroClip and GasAlertMax
XT from the docking module until the DATA TRANSFER
PASS LED lights green to indicate the transfer is
complete.

After the data transfer is complete, the detector deactivates
after 5 minutes of inactivity.

For more information about the Automatic Datalog Download
option, refer to the MicroDock II Base Station User Manual.

Eventlogging

Bump tests and calibrations are recorded on a

MultiMediaCard (MMC). The MMC is located on the base sta-
tion in the battery compartment. It stores test records that can
be downloaded from the base station to a PC.

Access Test Results

To access and view test results, refer to Importing Data into
Fleet Manager II
and Viewing Data in Fleet Manager II in the
Fleet Manager II Technical Reference Guide.

Configuring the Detector

(Not applicable to the

GasAlertClip Extreme)

Use Fleet Manager II to configure the following detectors:

• GasAlert Extreme
• GasAlertMicro
• GasAlertMicro 5/PID/IR

Advertising