Figure 3-4, Figure 3-5, Figure 3-6 – Honeywell ULTRAKEY LITE HJC5000 User Manual
Page 34: Videoblox serial port rs422 connection example, Shipment. see
34
Installing UltraKey Lite with VideoBloX
Figure 3-4
RJ45 to DB9 Male Adapter for VideoBloX and VideoBloX Lite CPUs
Figure 3-5
Direct RJ45 Serial Port Connection for VideoBloX NetCPUs
Figure 3-6
VideoBloX Serial Port RS422 Connection Example
Step 2: Configure the Controller for VideoBloX Mode
Note
The controller factory defaults are VideoBloX mode, Address 1, baud rate
19200 bps. If any other mode has been selected then use the following steps
to select VideoBloX mode. Otherwise skip to
Step 3: Configure Address, Baud
.
VideoBloX
RJ45 to DB9
male adapter
Serial Port
RJ45 network cable
Controller
VideoBloX
Serial Port
RJ45 network cable
Controller
VideoBloX Serial Port (RS422)
VIdeoBlox Master
Connections
RJ45 to
DB9 Male
VB master:
1--RS422_TX –
2--RS422_TX +
3--RS422_RX +
4--RS422_RX –
5--GND
RJ45 to
DB9 Male
RJ45
Network
Cable
1
RJ45 define:
1--RS485_2+/RS422_2_TX+/
RS422_1_RX+
2--RS485_2-/RS422_2_TX-/
RS422_1_RX-
3—NC
4--RS232RX
5--RS232GND
6--RS232TX
7--RS485_1-/RS422_1_TX-
8--RS485_1+/RS422_1_TX+
*RS485_2/RS422_2_TX and
RS232 use same UART_AC
#3
#4
#5
#1
#2
DB9
#8
#7
#5
#2
#1
RJ45
RX+
RX-
GND
TX-
TX+
PI NOUT
Controller 1
Controller 32
5
5
PSU
3
5
RJ45
Network
Cable
1
PSU
3