Introduction user guide using the boiler, General information and safety instructions – Heatmaster 200 N User Manual

Page 4

Advertising
background image

2

INTRODUCTION

USER GUIDE

USING THE BOILER

It is compulsory to have your system serviced every
year by a competent engineer. In the event of heavy
use of the boiler, it may require servicing on a more
regular basis than once a year. In this case, contact
your installer for advice.

Starting the burner

In conditions of normal operation, the burner starts automatically if
the temperature of the boiler is below the set point and goes off
when this value is reached.

Control panel

The user must not attempt to gain access to the
components inside the control panel.

1. On/Off switch
This turns the HeatMaster on or off.

2. Control thermostat - 60 to 90°C
When using the HeatMaster

®

as a hot water generator only, the

temperature can be set between 60°C and 90°C.
If the HeatMaster

®

is used for both hot water and central heating, the

control thermostat would normally be set at 80°C to achieve optimum
operating conditions.

3. Summer/Winter switch
This turns the heating pump

(if fitted)

on or off.

4. Manual reset high limit thermostat
If the boiler temperature exceeds 103°C this safety device will
activate and the high temperature indicator will light up. To reset -
first allow the boiler to cool to below 60°C, unscrew the cap and
press the reset button using a pencil or similar pointed device,
replace the cap. If the fault persists, turn the boiler off and call an
engineer.

GENERAL INFORMATION
AND SAFETY INSTRUCTIONS

General information

This documentation forms part of the items delivered with the
appliance and must be given to the user to keep in a safe place!

This appliance must be serviced and repaired by an approved
installer, in accordance with current standards in force.

ACV declines all liability for any damage caused as a result of
incorrect installation or as a result of the use of components or
connections that are not approved by ACV for this application.

Temperatures

This boiler is designed for central heating systems
with a maximum outlet temperature of 90°C.
Therefore, the central heating pipelines and the
radiators must reach this temperature.

The waste-gas pipe lines must reach
temperatures in excess of 100°C.

The hot water can reach temperatures in excess
of 60°C.

Installation

Before installing and commissioning the boiler, first

carefully read this manual.
Position the HeatMaster

®

according to the safety rules and

standards in force. You must comply with the ventilation
requirements for the room where appliances of this type are
installed. All air vents must remain unobstructed at all times.

It is prohibited to modify the interior of the appliance in any way,
without the manufacturer’s prior written agreement.

Service

In order to ensure the appliance operates safely and correctly, it is
important to have it serviced and reconditioned every year by an
installer or an approved service company.

Faults

Despite the strict quality standards imposed on its appliances by
ACV during production, inspection, and transport, faults may occur.
Please immediately inform your approved installer about such faults.
Remember to give the fault code as it appears on the screen.

Only genuine factory parts may be used as replacement parts.
Please go to page 13 for a list of spare parts and their ACV
reference numbers.

Important note: ACV reserves the right to change the technical
characteristics and specification of its products without notice.

D A N G E R

HOT

I

O

Manual reset high

limit thermostat

Burner

lockout

indicator

Combined temperature

and pressure gauge

Time clock

Control

thermostat

ON / OFF

switch

Primary circuit low

water pressure

indicator

High limit cutoff

indicator

Summer / Winter switch