Ab/hp series, Bl series, Options – Honeywell Switches and Sensors User Manual
Page 130

128
www.honeywell.com/sensing
PRESSURE SENSORS
AB/HP Series
The AB-High Performance pressure transducer is extremely accurate down to
0.25% span over a wide compensated temperature range. Both zero and full-
scale temperature compensation are held to extremely narrow limits.
The transducer’s body is made in a configuration permitting its use as a ‘flush-
mounted’ device in situations where ease of cleaning or low-fluid volumes are
major requirements. It may also be mounted in an adaptor for more
conventional installations. Made from 316L or 15-5PH stainless steel, the AB/
HP offer premium performance and flexibility at OEM prices.
Approvals:
CE
Supply voltage:
5.0 Vdc, 6.0 Vdc max.
Signal conditioning:
Unamplified compensation
Compensated temperature range:
-1 °C to 71 °C (30 °F to 160 °F)
Port style:
Flush Diaphragm
Output type:
0 mV to 100 mV
+ Excitation: Red
+ Signal: Grn
– Excitation: Blk
– Signal: Wht
4 conductor
color coded
shielded cable
0.91 m long
(
3 ft. )
Shield
(drain)
23,8
max. dia.
(
0.935)
19,0 max. dia.
(
0.749)
A
Pressure sensitive surface
(diaphragm)
29,2
max.
(
1.15)
6,4
(
0.25)
OPTIONS
0,91 m (3 ft) 4-Conductor Shielded Cable
-54 °C to 93 °C (-65 °F to 200 °F)
MEASUREMENT TYPE
PRESSURE RANGE
REFERENCE
Absolute
0 psia to 15 psia
ABH015PAC1B
Absolute
0 psia to 50 psia
ABH050PAC1B
Gauge
0 psig to 6 psig
ABH006PGC1B
Gauge
0 psig to 25 psig
ABH025PGC1B
Gauge
0 psig to 15 psig
ABH015PGC1B
Sealed Gauge
0 psis to 100 psis
ABH100PSC1B
Sealed Gauge
0 psis to 200 psis
ABH200PSC1B
Sealed Gauge
0 psis to 500 psis
ABH500PSC1B
Sealed Gauge
0 psis to 1,000 psis
ABH01KPSC1B
Sealed Gauge
0 psis to 2,000 psis
ABH02KPSC1B
Sealed Gauge
0 psis to 3,000 psis
ABH03KPSC1B
Bendix High Temperature Connector
-54 °C to 149 °C (-65 °F to 300 °F)
MEASUREMENT TYPE
PRESSURE RANGE
REFERENCE
Absolute
0 psia to 25 psia
ABH025PABB
Sealed Gauge
0 psis to 3,000 psis
ABH03KPSBB
Sealed Gauge
0 psis to 10,000 psis
ABH10KPSBB
BL Series
The BL pressure transmitter has a conventional 4 mA to 20 mA output and is
available with accuracies to 0.25%. It has Factory Mutual approval as an
intrinsically safe device for use in hazardous areas. Class I, Division I, Groups
A through G (when used within approved barriers).
Approvals:
CE, FM
Supply voltage:
12.0 Vdc to 30.0 Vdc
Signal conditioning:
Amplified compensated
Operating temperature range:
-40 °C to 82 °C (-40 °F to 180 °F)
Compensated temperature range: -1 °C to 54 °C (-30 °F to 130 °F)
Port style:
Flush Diaphragm
Output type:
4 mA to 20 mA
Termination type:
Bendix Connector
A
B
C
D
E
F
CONNECTOR
PTIH-10-6P
20,6
79,0 max.
A
B
19,05 max.
(0.75)
23,75 max.
(0.875)
(3.125)
(0.75)
PRESSURE
SENSITIVE
DIAPHRAGM
A
B
C & D
E
+ EXCITATION
RETURN
ZERO BALANCE
CASE GROUND
OPTIONS
MEASUREMENT TYPE
PRESSURE RANGE
REFERENCE
Gauge
0 psig to 15 psig
BLH015PGBG
Gauge
0 psig to 15 psig
BL015PGBG
Sealed Gauge
0 psis to 100 psis
BL100PSBG
Sealed Gauge
0 psis to 100 psis
BLH100PSBG
Sealed Gauge
0 psis to 200 psis
BL200PSBG
Sealed Gauge
0 psis to 500 psis
BL500PSBG
Sealed Gauge
0 psis to 5,000 psis
BL05KPSBG
Sealed Gauge
0 psis to 10,000 psis
BLH10KPSBG
PRESSURE RANGE (PSI)
)
I
S
P
(
e
g
n
a
R
e
r
u
s
s
e
r
P
X
A
M
A
.
m
i
D
B
.
m
i
D
5
-
0
1
7
2
.
)
9
.
6
(
5
2
.
)
4
.
6
(
0
5
-
0
o
t
5
1
-
1
2
3
2
.
)
9
.
5
(
5
2
.
)
4
.
6
(
0
0
2
-
0
o
t
0
0
1
-
0
8
3
2
.
)
1
.
6
(
5
2
.
)
4
.
6
(
0
0
0
1
-
0
o
t
0
0
5
-
0
8
3
2
.
)
1
.
6
(
9
1
.
)
8
.
4
(
0
0
0
5
-
0
o
t
0
0
0
2
-
0
3
7
2
.
)
9
.
6
(
9
1
.
)
8
.
4
(
0
0
0
5
1
-
0
o
t
0
0
0
0
1
-
0
7
8
2
.
)
3
.
7
(
9
1
.
)
8
.
4
(
0
0
0
0
2
-
0
5
8
2
.
)
5
.
7
(
9
1
.
)
8
.
4
(