Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev F • 1/2011

5

Asphyxiation Risk
This appliance produces carbon monoxide

(CO).

• The free opening areas (in square inches)

of the chimney damper as shown in the

following tables must be met.

• User must make sure damper is locked

open.

• The installer is responsible to ensure

proper ventilation of flue gases before

appliance is used.

Fire needs to draft properly for safe

operation.

WARNING

G. Negative Pressure

Negative pressure results from the imbalance of air avail-

able for the fireplace to operate properly. Causes for this

imbalance include:

• Exhaust fans (kitchen, bath, etc.).

• Range hoods.

• Combustion air requirements for furnaces, water heaters

and other combustion appliances.

• Clothes dryers.

• Location of return-air vents to furnace or air

conditioning.

• Imbalances of the HVAC air handling system.

• Upper level air leaks: recessed lighting, attic hatch

opening, duct leaks.

Table 1 for Factory Built Fireplaces

Free Opening Area (in square inches) of Chimney Damper for Venting combustion

Products from Decorative Appliances for Installation in Solid Fuel Burning Fireplaces.

Chimney Ht.

(Feet)*

GO318

GO 24 & 324

GO 30 & 330

10

not approved

not approved

not approved

15

38.5

38.5

45.4

20

31.2

31.2

37.4

25

27.3

27.3

31.2

30

24.6

24.6

28.3

35

22.1

22.1

25.5

40

20.4

20.4

23.8

Table 2 for Masonary Built Fireplaces

Free Opening Area (in square inches) of Chimney Damper for Venting combustion Products

from Decorative Appliances for Installation in Solid Fuel Burning Fireplaces.

Chimney Ht.

(Feet)*

GO318

GO 24 & 324

GO 30 & 330

6

64

64

71.4

8

59.7

59.7

66.9

10

54.3

54.3

60.2

15

48.8

48.8

54.1

20

44.4

44.4

49.1

30

40.3

40.3

44.5

* Height is measured from the hearth to the top of the chimney.

Minimum height is 6 ft.

Table 3 for Minimum Fireplace Dimensions

Log Set

Front

Opening

Depth

Height

Rear

Width

Natural

BTU

GO24

32 in.

20 in.

18 in.

21 in.

73,000

GO30

38 in.

20 in.

18 in.

27 in.

80,000

GO318

32 in.

23 in.

22 in.

21 in.

77,000

GO324

34 in.

23 in.

22 in.

22 in.

86,000

GO330

40 in.

23 in

22 in.

29 in.

86,000