peCifiCatioNs

GMVM96

0603BX

GMVM96

0805CX

GMVM96

1005DX

GMVM96

1155DX

GCVM96

0604CX

GCVM96

0805DX

GCVM96

1005DX

Heating Capacity
High Fire Input¹

60,000

80,000

100,000

115,000

60,000

80,000

100,000

High Fire Output¹

57,600

76,800

96,000

109,250

57,600

76,800

95,000

Low-Fire Steady-State Input¹

30,000

40,000

50,000

57,500

30,000

40,000

50,000

Low-Fire Steady-State Output¹

28,800

38,400

48,000

54,625

28,800

38,400

47,500

AFUE²

96

96

96

95

96

96

95

Tons AC @ 0.5” ESP

1.5-3.0

2.0-5.0

2.0-5.0

2.0-5.0

1.5-4.0

2.0-5.0

2.0-5.0

Temperature Rise Range (°F)

20-50

35-65

35-65

35-65

20-50

20-50

25-55

Circulator Blower
Size (D x W)

10" X 8"

11" X 10"

11" X 10"

11" X 10"

10"X 10"

11" X 10"

11" X 10"

Horespower @ 1050 RPM

3/4

1

1

1

3/4

1

1

Speed

Variable

Variable

Variable

Variable

Variable

Variable

Variable

Vent Diameter³

2"

3"

3"

3"

2"

3"

3"

No. of Burners

3

4

5

5

3

4

5

Disposable Filter (in²)

731

683

853

981

731

975

1,056

Electrical Data
Min. Circuit Ampacity (amps)⁴

6.0

14.2

14.2

14.2

6.0

14.2

14.2

Max. Overcurrent Protection⁵

15.0

15.0

15.0

15.0

15.0

15.0

15.0

Ship Weight (lbs)

135

145

170

170

139

165

170

¹ Natural Gas BTU/h
² DOE AFUE based upon Isolated Combustion System (ICS)
³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in

diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent
on installation/code requirements and must be 2” or 3” diameter PVC.

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical

Codes. Extensive wire runs will require larger wire sizes.

⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of

the same size as noted.

Notes

• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½” FPT
• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.