model g0555/g0555p (mfg. Since 5/11)

Table Tilt calibration

When properly adjusted, the positive stop bolt
enables the table to be quickly returned perpen-
dicular with the blade.

to tilt the table to the left, the positive stop bolt
must be lowered from its correct height, then re-
adjusted after the table is returned to 0°.

Tools Needed

Qty

Wrench 13mm ....................................................1
phillips Screwdriver #2 .......................................1
machinist's Square .............................................1

To set the positive stop 90˚ to the blade:

1. make sure the blade is correctly tensioned as

described in the

Tensioning Blade subsec-

tion earlier in this manual.

2. diSConneCt BAndSAW From poWer!

3. loosen the two table lock knobs that secure

the table to the trunnions.

4. loosen the hex nut that locks the positive

stop bolt in place.

5. Completely raise the upper blade guide

assembly, then place the machinist's square
flat on the table and against the side of the
blade, as illustrated in the figure below.

Positive

Stop

Table

Square

figure 37. Using a square to adjust the table

perpendicular to the side of the blade.

6. raise or lower the positive stop bolt until the

table is perpendicular to the side of the blade,
then re-tighten the hex nut against the cast-
ing to secure the setting.

7. rest the table on the positive stop bolt, then

re-tighten the table lock knobs to secure the
table perpendicular to the side of the blade.

8. observe the position of the table tilt pointer

on the tilt scale located underneath the front
of the table (see the figure below).

9. if the pointer is not correctly positioned at the

0° mark, then loosen the pointer screw, posi-
tion the pointer at the 0° mark, and re-tighten
the screw to hold it in place.

figure 36. positive stop bolt set at 90° (viewed

from behind the table).

positive

Stop Bolt

figure 38. location of the table tilt scale.

tilt Scale

pointer