Troubleshooting

6-16

Miscellaneous Problem Troubleshooting Table

SYMPTOM

CAUSE

REQUIRED ACTION

Faulty fluorescent
tube

1. Remove fluorescent tube from its sockets. If you

find cracks or darkened ends, install new lamp.
Clean tube.

2. Check continuity of both fluorescent tube

filaments.

3. Verify that fluorescent tube operates by placing it

in working VGM.

Faulty lamp fixture

Verify that lamp pins make good connection with
socket contacts.

Marquee lamp is intermittent
or non-functional

VGM (video game machine)
starts and plays normally

Faulty wiring

Measure fluorescent lamp AC voltages. Check
wiring and connector continuity from AC power
chassis to lamp assembly.

Obstructed fan

1. Check bottom and rear of cabinet for blocked

airflow.

2. Move VGM away from sources of heat.
3. Turn off VGM power. Remove dust from vent

holes with high-power vacuum cleaner.

Faulty wiring

Check fan wiring and connectors.

VGM operates normally

Cabinet becomes warm after
several hours of use

Faulty fan

Check operation of all fans.

Error messages appear on
screen

Faulty hardware

1. Check any assembly (RAM, ROM, Battery, etc.)

identified in error messages.

2. Call your authorized distributor for help with

unresolved screen messages.

Fan Location and Mounting