Troubleshooting

6-2

Coin Mechanism and Pricing Troubleshooting Table

SYMPTOM

CAUSE

REQUIRED ACTION

Improper settings at
Pricing Menu

1. Enter Menu System by pressing and holding

TEST MODE switch inside coin door. From
Diagnostics Menu, choose SWITCH TEST. Use
tests to confirm operation of switches.

2. From Adjustments Menu, choose PRICING

MENU. Verify that units and credits are set
correctly.

VGM (video game machine)
accepts currency or tokens,
but number of credits per
coin or bill is incorrect.

Faulty wiring

1. Check that cabinet wiring is correct for this VGM.
2. Assure that coin meter and coin switches

connect properly to control input wires.

Improper currency

1. Unlock and open cash door. Empty cash box.

Inspect revenue for counterfeit currency.

2. Check vault. Remove any items that block path

from mechanism.

Faulty coin
mechanism

1. Unlock and open coin door. Check each

mechanism for proper mounting.

2. Remove mechanism.
3. Clear currency path.
4. Reinstall mechanism and latch it.

VGM won’t accept currency
or tokens.

VGM won’t start.

Audio and video are present.

Tilted coin
mechanism or VGM

1. Verify that mechanism is level after doors close.
2. Repair or replace coin door if it is bent or

damaged.

3. If necessary, adjust cabinet leg levelers to keep

mechanisms vertical.

Burned-out bulb

1. Burned-out bulbs may appear white or darkened.

Check continuity with DVM.

2. Replace burned-out bulb with same type.

Coin indicators don’t light

Open fuse circuit

1. Check fuse continuity with DVM.
2. If fuse is blown, replace fuse with same type.
3. If fuse isn’t blown, check wiring.

CAUTION: Don’t remove or install any connector when power is turned on. Installation
under power will damage the circuit boards or hard disk drive and void the warranty.