Caution

Caution

Multitec

19

7.3.5.2 Removing an air-cooled mechanical seal

(seal code 64)

Fig. 33
N.B.: This mechanical seal design is used for application

temperatures from 140 to 200°C and Multitec sizes 32 to 100.

The pump shall only be coupled to a motor with enclosure IP 55.

- Remove the bearing as described in sections 7.3.3.1 and

7.3.3.2.

- Remove O-ring 412.10.

- Pull off spacer sleeve 525.1.

- Loosen bolts 901.11.

- Remove bearing housing 350.1.

- Remove mechanical seal cover 471.1 with the seat ring and

gasket 400.1.

- Remove key 940.5.

- Pull off sleeve 523.1 with the rotating assembly of

mechanical seal 433.7. (Two holes are provided in the

sleeve for engaging a puller.)

- Take off seal housing 441.4.

- Remove O-ring 412.4.

On between-bearings pumps (pump version C or D) the

mechanical seal shall be removed as follows:

- Remove screws 900.2 and hood 683.1.

- Undo axis 87-5 with fan impeller 831.1.

- The threaded insert 915 must remain in the shaft 210.

On previous versions (prior to 03/2002) and if

assembled in the factory, the fan shaft 87-5 was

fitted using Loctite 222.

On previous versions and when re-assembling,

secure fan shaft 87-5 and fan impeller 831.1 with

Loctite 222.

- Remove support 59-7.

- Remove the bearing as described in section 7.3.3.1 as well

as spacer sleeve 525.1 and bearing housing 350.1.

Remove the mechanical seal as described above.

Fig. 34

7.3.5.3 Removing a water-cooled mechanical seal (seal

code 64)

Fig. 35

Note: This mechanical seal design is used for temperatures

from 140 to 200°C and sizes 125 and 150 (optional for sizes

32 to 100).

-

Drain the pump and remove the circulation line at the

pipe union 731.15.

-

Remove the rolling element bearing as described in sec-

tions 7.3.3.1 and 7.3.3.2.

-

Remove O-ring 412.10.

-

Pull off spacer sleeve 525.1.

-

Undo nuts 920.3.

-

Remove bearing housing 350.1.

-

Remove mechanical seal cover 471.1 with the seat ring

and gasket 400.1.

-

Remove key 940.5.

-

Pull off sleeve 523.1 with the rotating assembly of mech-

anical seal 433.7. (Two holes are provided in the sleeve

for engaging a puller.)

-

Remove cooling jacket 66-2.

-

Take off seal housing 441.4.

-

Remove O-ring 412.4.

7.3.5.4 Removing a double-acting mechanical seal

Mechanical seals in tandem and back-to-back arrangement are

fitted as per customer specifications. There is a wide variety of

variants, types and brands. Please refer to the general

assembly drawing and the documentation supplied with the

pump for orientation.