1 - 16

Cajun P880 Routing Switch Installation Guide

1

* Note: The following tables describe maximum link distances

only. When building half-duplex networks using
Ethernet repeaters, you must also consider maximum
network diameter, which is not discussed in this
document.

Table 4. Maximum Fiber Link Distances for 100 Mb/s

Links

Fiber Cable Description

Maximum Cable
Length

Half-duplex connection

412 m

Full-duplex connection

2 km

Table 5. Maximum Copper Cable Lengths (10/100 Mb/s

Links)

Cable Description

Maximum Cable
Length

Category 5 twisted pair cable

100 m