Maintenance procedures, Adjusting arm angle and tension – Invacare 1900 User Manual

Page 19

Advertising
background image

SECTION 3—MAINTENANCE AND TROUBLESHOOTING

Part No. 1148113

19

1900/1900S Bath Lift

Maintenance Procedures

Adjusting Arm Angle and Tension

ƽ WARNING

The lift arms should be tight and secure when in the up or lifted position. If the lift

arms are not tight, they may fall causing injury to either resident or attendant and

damage to the lift.

NOTE: For this procedure, refer to FIGURE 3.1.

1. Remove the lift shroud by pulling up on it, disengaing the hook‐and‐loop strip that 

secures the shroud to the lift frame.

2. Do one or both of the following:

To adjust the angle ‐ Depending on the angle, either tighen or loosen one of the 

four jam nuts that rest on either stopping plate (Detail “A”).

To adjust the tension ‐ Depending on the tension, either tighten or loosen one of 

the four jam nuts controlling arm tension (Detail “B”).

3. Tighten the arm clamp.

NOTE: Tighten the arm until it is secured and stable in a lifted position.

4. Install the lift shroud.

FIGURE 3.1 Adjusting Arm Angle and Tension

Jam Nut

Arm

Stopping Plates

Jam Nuts

Arm

DETAIL “A” - ADJUSTING ARM ANGLE

DETAIL “B” - ADJUSTING ARM TENSION

Advertising
This manual is related to the following products: