IBM EGX-400 User Manual

Page 65

Advertising
background image

61

Chapter 4 - Performing Cutting Using a Computer

4-2. Setting the Cutting Parameters

Cutting-in Depth and Cut-out Amount

Setting the Cutting-in Depth

1

Press

. Press

to move the blinking cursor to

[Z1].

2

Use

to set the cutting-in amount. If the value is

[------], then hold down

until it changes to a numerical

value.

At this time the spindle moves up and down and the position when cut-
ting-in is performed (the Z1 position) is displayed. You can set the cut-
ting-in depth as you verify the actual Z1 position.

3

Press

.

Setting the Cut-out Amount

1

Press

. Press

to move the blinking cursor to

[Z2].

2

Use

to set the cut-out amount. If the value is

[------], then hold down

until it changes to a numerical

value.

At this time the spindle moves up and down and the position of cut-out
(the Z2 position) is displayed. You can set the cut-out amount as you
verify the actual Z2 position.

3

Press

.

Important Notes on Setting the Cutting-in Depth

The cutting-in depth is a setting that indicates the amount of lowering from the Z-axis reference point (the Z0 position). If
the Z0 position changes, then the cutting-in position (the Z1 position) also changes by a corresponding amount.
The Z1 position cannot be set above the Z0 position. When the spindle is above the Z0 position, the value displayed is
[------], indicating that the setting cannot be made at this position.

Unit of Measurement for the Numerical Values

The measurement unit for the displayed values is 0.01 mm. When [-20] is displayed, for example, the cutting-in amount is
0.2 mm.

Important Notes on Setting the Cut-out Amount

The cut-out amount is a setting that indicates the amount of rise from the Z-axis reference point (the Z0 position). If the Z0
position changes, then the cut-out position (the Z2 position) also changes by a corresponding amount.
The Z2 position cannot be set below the Z0 position. When the spindle is below the Z0 position, the value displayed is
[------], indicating that the setting cannot be made at this position. This means that you cannot set a cut-out amount when the
Z0 position is at the highest point on the Z axis.

Unit of Measurement for the Numerical Values

The measurement unit for the displayed values is 0.01 mm. When [100] is displayed, for example, the cut-out amount is 1
mm.

SET Z1 Z0

Z

2

UP < 0 >

SET

Z

1 Z0 Z2

DOWN < 0 >