Command Reference Guide

/C

Connect

Establishes a bidirectional connection between two ports. For more

information, see Section 6.2.3. There are two types of connections:

Resident Connect: If the /C command specifies only one port, your

resident port will be connected to the specified port.

Third Party Connect: If the /C command specifies two ports, the unit

will connect the two ports indicated. Third Party Connections can only be

initiated by ports and accounts that permit Supervisor commands.

Notes:

• If your user account does not permit Supervisor commands, you

will only be allowed to connect to ports specifically allowed by that

account.

• Non-Supervisors cannot create Third Party connections; Non-

Supervisors are only allowed to create connections between their

resident port and the ports allowed by their password/account.

• If the user account permits Supervisor commands, you are allowed

to connect to any port.

• RS232 Ports are not allowed to create a Third Party connection to

the Network Port. For example, Port 1 cannot connect Port 3 to the

Network Port.

Availability: Supervisor / Non-Supervisor
Format:

/C <x> [x] [Enter]

Where

x is the number or name of the port(s) to be connected.

Response:

Verbose: "Connected x x." When a Resident Connection is initiated, the

CMS-6R4 will also display the Resident Disconnect Sequence.

Terse: 1