ICP DAS USA MSM-6226 User Manual

Page 256

Advertising
background image

9
10
11
12
13
……


set flow-control


Syntax
:
set flow-control <range> <symmetric | asymmetric>
Description:
To set up the flow control function of all ports.
Argument:
<range>:port range, syntax 1,5-7, available from 1 to 26
<symmetric>: set its flow control as symmetric
<asymmetric>: set its flow control as asymmetric
Possible value:
<range>: 1 to 26
<symmetric | asymmetric>:symmetric or asymmetric
Example:

FEL2P-SW26 (port)# set flow-control 3-6 asymmetric


set speed-duplex


Syntax
:
set speed-duplex <range> <auto>|[<10|100|1000> <half | full>]
Description:
To set up the speed and duplex of all ports.
Argument:
<range>:port range, syntax 1,5-7, available from 1 to 26
<port-speed>:
auto : set auto-negotiation mode
10 : set speed to 10M
100 : set speed to 100M
1000 : set speed to 1000M
<port-duplex> :
half : set to half duplex
full : set to full duplex
Possible value:
<range>: 1 to 26
<port-speed> : auto, 10, 100, 1000
<port-duplex> : full, half
Example:

FEL2P-SW26(port)# set speed-duplex 10-15 10 full
FEL2P-SW26(port)# show status
asymmetric: set
5 TP Up Enable Enable 100M/Full ON OFF
6 TP Down Enable Enable ----/---- ---- ---- Engineer
7 TP Down Enable Enable ----/---- ---- ----
8 TP Down Enable Enable ----/---- ---- ---- sales

Advertising