Hardware Maintenance Manual: xSeries 330

2-1-1

(Secondary DMA register

failed)

1.

System Board

2-1-2

(Primary DMA register failed)

1.

System Board

2-1-3

(Primary interrupt mask

register failed)

1.

System Board

2-1-4

(Secondary interrupt mask

register failed)

1.

System Board

2-2-2

(Keyboard controller failed)

1.

Keyboard

2.

System Board

2-2-3

(CMOS power failure and

checksum checks failed)

1.

Battery

2.

System Board

2-2-4

(CMOS configuration

information validation failed)

1.

Battery

2.

System Board

2-3-1

(Screen initialization failed)

1.

System Board

2-3-2

(Screen memory failed)

1.

System Board

2-3-3

(Screen retrace failed)

1.

System Board

2-3-4

(Search for video ROM failed)

1.

System Board

2-4-1

(Video failed; screen believed

operable)

1.

System Board

3-1-1

(Timer tick interrupt failed)

1.

System Board

3-1-2

(Interval timer channel 2

failed)

1.

System Board

3-1-3

(RAM test failed above

address OFFFFH))

1.

DIMM

2.

System Board

3-1-4

(Time-Of-Day clock failed)

1.

Battery

2.

System Board

3-2-1

(Serial port failed)

1.

System Board

3-2-2

(Parallel port failed)

1.

System Board

3-2-4

(Failure comparing CMOS

memory size against actual)

1.

DIMM

2.

System Board

3.

Battery

3-3-1

(Memory size mismatch

occurred; see "Memory Settings" on
page 33)

1.

DIMM

Board

2.

System Board

3.

Battery

3-3-2

(Critical SMBUS error

occurred)

1.

Disconnect the server power cord from outlet, wait 30 seconds and retry.

2.

System Board

3.

DIMMs

4.

DASD Backplane

5.

DASD Power Cable