SSI

ERP2U Power Supply Design Guide, V2.31

- 17 -

2.

If 240VA limiting is not a requirement for the power supply than all +12V outputs are common and may have the same

wire color.

6.1.5

Serial ATA Power Connector

STATUS

Optional

This is a required connector for systems with serial ATA devices.

The detailed requirements for the serial ATA connector can be found in the “Serial ATA : High Speed Serialized
AT Attachment “ specification at

www.serialata.org

.

Molex Housing #675820000

Molex Terminal #67510000

Table 11: Floppy Power Connector

Pin

Signal

18 AWG Color

5 +3.3VDC

Orange

4 COM

Black

3 +5VDC

Red

2 COM

Black

1 +12V4

Yellow/Green

Stripe

Serial ATA Connector

5

4
3
2

1

6.1.6

Server Signal Connector

STATUS

Optional

For server systems with SMBus features, the power supply may have an additional connector, which provides
serial SMBus for FRU data and remote sense on 3.3V and Return. If the Server Signal connector is not present,
the 3.3V remote sense will be double crimped into one of the 3.3V power contacts in the Baseboard power
connector.

Connector housing: 5-pin Molex 50-57-9405 or equivalent

Contacts: Molex 16-02-0088 or equivalent

Table 12: Server Signal Connector

Pin

Signal

24 AWG Color